Forskning ved Københavns Universitet - Københavns Universitet

Forside

Influence of tissue preservation methods on arterial geometry and echogenicity.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskning

  • H. Sillesen
  • J Wilhjelm
  • Katja Vogt
  • S.K. Jespersen
original, ultrasound, ultrasonic measurement, vessel diameter, wall thickness, measurement of echogenicity, freezing of specimen, formalin fixation, pressurized formalin fixation, porcine artery
OriginalsprogEngelsk
TidsskriftUltrasound Med Biolo
Udgave nummer23/7
Sider (fra-til)1071-1082
StatusUdgivet - 1997

ID: 216660